Sets the Standard for Laboratory and Production:
eddyliner®P

eddyliner®P

Structure Test with eddyliner®P:
Preventive multi-frequency test
with simple operation

l

l

l

l

Only OK parts
 required for calibration

Preventive multi-frequency testing with 8 frequencies

Automatic generation
of all 8 tolerance zones

Convenient display
of all test results

The eddyliner®P is an eddy current instrument designed for testing material mix, heat treatment (hardness, case depth, temper, etc.), sinter density and structure differences.
The eddyliner®P is specifically designed for versatility in production line or laboratory use and its principle of operation is based on ibg's preventive multi-frequency testing (PMFT). Thus it provides a far greater degree of reliability than single-frequency eddy current instruments.
 Operation is supported by a user friendly complete on-board computer to simplify and speed up calibration and sort procedures. Use of leading edge electronic techniques allows extremely short testing times despite multi-frequency scanning.
The eddyliner®P is available in different case options. Using an opto-isolated interface the instrument can be integrated in automatic test processes. As a standard feature it is completely equipped with all displays and interfaces for universal use.
Preventive Multi-Frequency Method:
Only OK parts are required for calibrating the eddyliner®P. During calibration known reference parts are tested over a broad frequency band (1:1000 bis 1:3000) with up to 8 frequencies. Subsequently a typical impedence curve develops. Like a fingerprint it reflects the different characteristics of material like alloy, structure and scattering of the known OK parts.
Due to very easy operation the eddyliner®P can quickly be brought into the test mode. Testing is also carried out with 8 frequencies. OK decisions are only reached if all and every criteria of the test part correspond to the known data. Thus unexpected deviations are recognized and sorted out. Test reliability is significantly higher compared with single-frequency testing.
Test Routine:
Test result is either "OK" or "NOK". It is shown by a green or red indicator lamp and transmitted to the outside by an optoelectronic interface.

Technical Data:

l

l

l

l

Easy to operate, even by
 semi-skilled personnel

High-speed testing
 within milliseconds

Maximum stability due to
 automatic self-calibration

Maximum test reliability
 to find unexpected defects

After each test the integrated statistic evaluation is After each test the measured values are statistically updated with numerical and percentage information.
Data Storage:
Up to 16 possible frequency band combinations may be selected for calibration purposes. Moreover, 50 complete set-ups can be stored for future access.
Every test set-up can be stored on a so called external "Memory Plug”. The "Memory Plug" is simply plugged in at the front panel and thus makes transmission of one test set-up to other eddyliner®P units possible.
 Documentation and Data Transfer:
The eddyliner®P is equipped with a standard Centronics interface for communication with external printers to provide hardcopy print-outs of test results.
An integrated RS232/V24 interface permits communication with separate main-frame computers to perform statistical analysis (SPC) of accumulated data.
Opto-isolated Interface:
With the standard opto-interface external control signals can be transferred to the eddyliner®P and sorting decisions can be transmitted to peripheral accessories. (Examples: test initiation via light barrier, transfer of sorting decision to gate mechanism, optical and/or acoustic alarm signal)
Coils and Probes:
Suitable coils and probes are available for all applications. Besides the wide range of standard coils special coils for all frequency ranges and dimensions can be made to meet customer's specification.
Case Options:
The eddyliner®P is available in the desktop version (P/N 84001-B) or rack mount housing (P/N 84011B).

Test Routine:
 Test frequency range:
Test Time:
Display:
Microprocessor:
Standard Interfaces:



Mains connection voltage:
Power requirement:
Dimensions:
Weight:

Preventive Multi-Frequency Testing with up to 8 test frequencies
5 Hz – 300 kHz
8 ms/frequency (min.)
LCD-Display 125mm x 77mm, background lighting
brightness and contrast adjustable
 2 x 16 bit CPU for maximum test speed
Centronics printer-interface for documentation
RS232/V24 computer-interface
opto-interface for system integration (PLC)
85 – 240 V AC, 50/60 Hz
50 VA
W 364mm x H 147mm x D 262mm (desktop version)
7 kg

(Technical data are subject to change without prior notice)