Reliability  Multiplied:

eddyliner®P2/P3/P4/P16

eddyliner® P2 / P16

Structure Testing with eddyliner®P2/P3/P4/P16:
Preventive Multi-Frequency Testing
with up to 16 Channels in one  Instrument

l

l

l

l

Only OK parts
 required for  calibration

PMFT with 8 test frequencies
at every channel

Automatic generation of all
8  tolerance zones per channel

Convenient display
of all test  results

The eddyliner®P2/P3 /P4/P16 eddy current  instruments are designed for testing material mix, heat treatment (hardness, case depth, temper, etc), sinter density and structure differences on various test areas of one test part. (The number indicates the utilizable channels: 2, 3, 4 or 16.)
The eddyliner®Px is  specifically designed for versatility in production and  its operation principle is based on ibg's multi-frequency testing (PMFT). Thus it provides a far  greater degree of reliability than single-frequency eddy  current instruments.
 Operation is supported by a user-friendly complete on-board computer to simplify  and speed up calibration and sort procedures. Use of  leading edge electronic techniques allows extremely short test times despite multi-frequency  scanning.
Using an optoelectronic interface the eddyliner®Px can be integrated into automatic test  processes. As a standard feature the instrument is completely equipped with all displays and interfaces.
Preventive Multi-Frequency Method:
 Only OK parts are required for  calibration of the eddyliner®Px. During calibration these known reference parts are tested over  a broad frequency band (1:1000 to 1:3000) with up to 8 frequencies per test area. A typical impedence curve develops. Like a fingerprint it reflects the different  characteristics of material such as alloy and structure as well as scattering of the known OK parts.
Due to very easy operation the eddyliner®Px can quickly  be brought into test mode. Testing is also carried out  with up to 8 frequencies at each position. The  instrument only decides on OK if the overall view of the test part corresponds to the recorded data. Thus unexpected deviations are detected and sorted out. Test  reliability is significantly improved as compared to  with the old single-frequency method.
Test Routine:
Test result is either ”OK” or ”NOK”. It  is shown by a green or red indicator lamp and is available at optically isolated outputs.

Technical Data:

l

l

l

l

Easy to operate, even by
 semi-skilled  personnel

High-speed testing
 within  milliseconds

Maximum stability due  to
 automatic self-calibration

Maximum test reliability
 to  find unexpected defects

After each test the integrated statistical evaluation is updated with numerical and percentage  information.
Data Storage:
Up to 16 possible frequency band combinations can be selected at the eddyliner®Px for calibration purposes.  Moreover, 50 complete instrument set-ups can be stored  for future access.
Each test set-up can also be stored externally on a so-called ”Memory Plug”. The Memory Plug is simply plugged in at the front panel and thus makes transmission of one test set-up to other eddyliner®Px units possible.
 Documentation und Data  Transfer:
The eddyliner®Px is equipped with a standard Centronics Interface for communication with external printers to provide hardcopy print-outs.
An integrated RS232/V24 interface permits  communication with separate main-frame computers to perform statistical analysis (SPC) of accumulated  data.
Opto-isolated Interface:
 With  the standard opto-interface external control signals can  be transferred to the eddyliner®Px and sorting  decisions can be transmitted to peripheral accessories  (Examples: test initiation via light barrier, transfer  of sorting decision to gate mechanism, optical and/or  acoustic alarm signals).
Coils and  Probes:
Suitable coils and probes are available  for all applications. Besides the wide range of standard accessories, coils for all frequency ranges and  dimensions can be made to meet customer’s  specification..

Test Routine:

Test frequency range:
Test Time:
Display:
Microprocessor:
Standard Interfaces:



Mains connection voltage:
Power  requirement:
Dimensions:
Weight:

Preventive Muti-frequency testing with
up to  8 test frequencies on 2, 3, 4 or 16 channels
5 Hz – 300 kHz
8 ms/frequency und channel (min.)
LCD-Display 125 mm x 77 mm, background lighting
 brightness and contrast adjustable
2 x 16 bit P for maximum test  speed
Centronics printer-interface for documentation
RS232/V24  computer-interface
opto-interface for system  integration (PLC)
85 – 240 V AC, 50/60 Hz
50 VA
B 364 mm x H 147 mm x D 262 mm (desktop  version)
7 kg